Docs/Switches

From MTU LUG Wiki
Jump to navigation Jump to search

~/Docs

For Layer 1 network details, see Docs/Cables.

For Layer 3 network details, see Docs/OPNSense.

VLANs

Network VLAN ID
Management 1
LAN 2
???? 30
WAN 640

Switch Ports

Fiber switch:

Switch port Client Client port VLAN 1 (Mgmt.) VLAN 2 (LAN) VLAN 30 (???) VLAN 640 (WAN)
1 Shell Excluded Untagged Excluded Excluded
2 Storage Excluded Untagged Excluded Excluded
3 Mirrors Excluded Untagged Excluded Excluded
4 Kurisu Excluded Untagged Excluded Excluded
5 Okabe Excluded Untagged Excluded Excluded
6 Daru Excluded Untagged Excluded Excluded
7 Mayuri Excluded Untagged Excluded Excluded
8 Luka Excluded Untagged Excluded Excluded
9 Watch Excluded Untagged Excluded Excluded
10 N/A Excluded Untagged Excluded Excluded
11 ravioli ix1 (left SFP) Tagged Tagged Excluded Excluded
12 lasagna Tagged Tagged Excluded Excluded
13 48 Port Port 45 Tagged Tagged Excluded Excluded
14 48 Port Port 46 Tagged Tagged Excluded Excluded
15 48 Port Port 47 Tagged Tagged Excluded Excluded
16 48 Port Port 48 Tagged Tagged Excluded Excluded

Ethernet switch:

WAN

Our WAN is a LAGG across two ports. The link needs LACP enabled ("Static mode" off in 1Gb Ubiquiti Switch) [1], and STP off.

IT configures their switches to automatically shut off ports if they detect STP advertisements.

Reference commands to make a Cisco switch satisfy the requirements:

(config-if)# spanning-tree bpdufilter enable
(config-if)# spanning-tree bpduguard disable